Two methods of coupling alignment adjustment

时间:2014-02-24 19:13 作者:admin 点击:
When installing the equipment, first install the driven machine (pump) so that its axis is in a horizontal position, and then install the master machine (micro-motor), so only the master machine needs to be adjusted when aligning, that is, the master machine (micro-motor) Add the method of adjusting the cushion surface under the feet to adjust.
Two methods for measuring and adjusting the timing:
1) Use a dial indicator and a meter frame or a special alignment tool to measure the misalignment and non-parallelism of the two couplings. This method can be used for rotating equipment with high speed, rigid connection and high precision requirements.
2) Use a knife-shaped ruler and feeler gauge to measure the misalignment of the coupling and use a wedge-shaped clearance rail or feeler gauge to measure the non-parallelism of the end surface of the coupling. This method is suitable for elastic couplings with low speed and low precision requirements. equipment.